BLMFF - 390-LINE LAMINATING RESINS, 35996

Product Identification

Product ID:390-LINE LAMINATING RESINS, 35996
MSDS Date:04/01/1989
FSC:8030
NIIN:00N020896
MSDS Number: BLMFF

Responsible Party
ICI AUSTRALIA OPERATIONS PTY LTD
1 NICHOLSON STREET
MELBOURNE
AU

Emergency Phone: 008-033111

Info Phone: 03-665-7111

Cage: Z0015

Contractor
ICI AUSTRALIA OPERATIONS PT LTD
MELBOURNE AU

Telephone: 03-665-7111

Cage: Z0015

Ingredients

REST UNTIL FULLY RECOVERED. IF BRTHG HAS STOPPED

RTECS: 9999999ZZ


APPLY EXTERNAL CARDIAC MASSAGE. IF BRTHG LABOURED

RTECS: 9999999ZZ


CLEAR & HAVE QUALIFIED PERSON GIVE AIR THRU FACE

RTECS: 9999999ZZ


DO NOT INDUCE VOMIT. SEEK IMMED MED ASSISTANCE.

RTECS: 9999999ZZ


PROVIDE ADTNL ASSISTANCE FOR SCHEDULED POISONS.

RTECS: 9999999ZZ


USE H*2O SPRAY TO DISPERSE VAP. COLLECT & SEAL

RTECS: 9999999ZZ


OCCURRED ADVISE LOCAL EMERGENCY SERVICES.

RTECS: 9999999ZZ


STYRENE, MONOMER (SARA III)

CAS: 100-42-5

RTECS: WL3675000

Fraction By Weight: 60%

OSHA PEL 100 PPM

ACGIH TLV: S,50PPM/100STEL;9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


& LOOSEN REMAINING CLTHG. ALLOW PATIENT TO

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) 5000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SHORT TERM EXPOS BY INHAL & SKIN CONT
IS CONSIDERED TO BE HARMFUL. SKIN: CONT W/SKIN WILL RSLT IN IRRIT.
RPTD/PRLNGD SKIN CONT MAY LEAD TO DERM EFTS. CAN BE ABSORB THRU
SKIN W/RESULTANT TOXIC EFTS. EY ES: A SEVERE EYE IRRIT. CONTAM OF
EYES CAN RSLT IN PERM INJ. INHAL: VAP IS IRRIT TO MUC MEMB & (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:STYRENE: IARC GRP 2B.
Effects of Overexposure:HLTH HAZ: RESP TRACT. INHAL OF VAP CAN RSLT IN
DROW, NAUS, HDCH, FATIGUE & DIZZ. INHAL OF HIGH CONC CAN PRDCE CNS
DEPRESSION, WHICH CAN LEAD TO LOSS OF COORDINATION, IMPAIRED
JUDGMENT &, IF EXPOS IS P RLNGD, UNCON. CHRONIC EXPOS CAN LEAD TO
STYRENE SICKNESS' W/SYMP OF NAUS, VOMIT, ANOREXIA, GEN WEAKNESS
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: IMMED WASH CONTAM SKIN W/PLENTY OF H2O. REMOVE CONTAM
CLTHG & WASH BEFORE RE-USE. IF SWELLING, REDNESS, BLISTERING/IRRIT
OCCURS SEEK MED ADVICE. EYES: IMMED IRRIGATE W/COPIOUS QTYS OF H2O
FOR AT LEAST 15 MIN. EYELIDS TO BE HELD OPEN.REMOVE CLTHG IF
CONTAM & WASH CONTAM SKIN. URGENTLY SEEK MED ASSISTANCE. TRANSPORT
TO HOSPITAL/MED CENTRE. INHAL: REMOVE VICTIM FROM EXPOS-AVOID (SUPP
DATA)

Fire Fighting

Flash Point:87.8F,31.0C
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL POWDER, BCF.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:FLAM LIQ. ON BURNING WILL EMIT NOXIOUS
FUMES. HEATING CAN CAUSE POLYM TO OCCUR LEADING TO VIOLENT RUPTURE
OF CNTNRS.

Accidental Release

Spill Release Procedures:CLEAR AREA OF ALL UNPROT PERSONNEL.WEAR FULL
PROT EQUIP TO PVNT SKIN & EYE CONTAM & INHAL OF VAPS.SHUT OFF ALL
POS SOURCES OF IGNIT.INCR VENT.CONT & PVNT RUN OFF INTO
DRAINS/WATERWAYS. USE ABSORB (SOI L/SAND, SAWDUST, INERT MATL,
VERMICULITE).(ING 8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:FLAM LIQ. AVOID ALL IGNIT SOURCES.
FLAMEPROOF EQUIP NEC IN USE AREA. GROUND NEARBY EQUIP. VAP HVR/AIR.
PVNT CONC IN HOLLOWS/SUMPS.
Other Precautions:DO NOT ENTER CONFINED SPACES WHERE VAP MAY HAVE
COLLECTED. STORE IN COOL PLACE & OUT OF DIRECT SUNLIGHT. STORE AWAY
FROM SOURCES OF HEAT/IGNIT. STORE AWAY FROM ORGANIC AND/OR
COMBUSTIBLE MATERIALS.

Exposure Controls

Respiratory Protection:IF INHAL RISK EXISTS WEAR NIOSH/MSHA APPROVED
ORGANIC VAP RESP. IF USING RESP, ENSURE THAT CARTRIDGES ARE CORRECT
FOR POTENTIAL AIR CONTAM & ARE IN GOOD WORKING ORDER.
Ventilation:USE WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR OVERALLS.
Work Hygienic Practices:ALWAYS WASH HANDS BEFORE SMOKING, EATING,
DRINKING OR USING THE TOILET. AVOID EYE AND SKIN CONTACT.
Supplemental Safety and Health
EFTS OF OVEREXP: & DFCLTY IN CONC. SOME ANIMAL TEST DATA SUGGESTS
CARCIN POTENTIAL FOR STYRENE. THESE PARTICULAR DATA ARE NOT
CONSIDERED RELEVANT TO NORMAL INDUSTRIAL USE BUT EMPHASIZE NEED FOR
CARE I N HNDLG. FIRST AID PROC: BECOMING CASUALTY. REMOVE CONTAM
CLTHG (SEE ING 2)

Chemical Properties

HCC:F4
Vapor Pres:0.6KPA@20C
Spec Gravity:1.091
Solubility in Water:INSOLUBLE
Appearance and Odor:PALE YELLOW LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Conditions to Avoid Polymerization:HEAT, STRONG ACIDS AND OXIDIZING
AGENTS CAN CAUSE POLYMERIZATION TO OCCUR, W/RELEASE OF HEAT AND
POSSIBLE EXPLOSION.

Disposal

Waste Disposal Methods:REFER TO STATE LAND WASTE MANAGEMENT AUTHORITY.
ADVISE FLAMMABLE NATURE. EMPTY CONTAINERS MUST BE DECONTAMINATED.
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS
.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.